Line Voltage

The recommended line voltage range for the Viper unit is 215 to 245VAC. Measure the voltage at the wall outlet to
verify proper wiring of the outlet before plugging the Viper unit in.

Power

The power circuit must have some sort of overload protection, such as a circuit breaker or fuse that meets local
and national electrical codes. Table 1. shows the power requirements for the various types of units.

Electrical Connections

To connect AC power to the unit, perform the procedure in Table 2. 60Hz units are supplied with the power cord
attached. Skip installation information in Table 2. and begin with the Water Supply Requirements section.
Step
1
2
3
4
5
6
7
8
9
Terminal
Block
Publication Number: 621360041TBINS
3-Barrel 60Hz
30 A. Circuit
Insure that power to the unit is off. DO NOT plug the power cord into the wall
outlet at this time.
Remove the right side and rear panel from the unit.
Remove the cover from the electrical box.
Feed the power cord through the strain relief, as shown in Figure 4.
Pull the slack out of cable and tighten the strain relief (see Figure 4.).
Connect the colored wire to the appropriate terminal on the terminal block.
Connect the black wire to the appropriate terminal on the terminal block.
Connect the green wire to the ground terminal next to the terminal block.
Replace the power box cover. DO NOT TURN ON THE POWER at this time.
Table 1.
3-Barrel 50Hz
30 A. Circuit
Table 2.
Action
Figure 4.
- 8 -