Technical Specifications; Preliminary Warnings; Preliminary Checks - GiBiDi TAIMEN T6 Instructions For Installation Manual

Electromechanical gearmotors
Hide thumbs Also See for TAIMEN T6:
Table of Contents

Advertisement

Available languages

Available languages

TAIMEN

TECHNICAL SPECIFICATIONS

Operator
Type
Supply voltage
Motor Supply voltage
Power absorbed
Max Force
Speed
Slow downs
Operating temperature
Degree of protection
Max door height
Max door surface
Operating frequency (%)
Radio receiver
Formula to calculate the
operating frequency

PRELIMINARY WARNINGS

Check that the door structure is in conformity with the regulations in force and that door movement is linear without
friction.

Preliminary checks:

Check that the door structure is sufficiently robust. In any case, check that the weight and dimensions of the door
Ÿ
fall within the limits of use of the operator;
Check that the door can be moved manually without force (points of greatest friction) for the entire travel of the
Ÿ
door during both opening and closing;
A garage door is deemed to be well balanced and aligned if it:
Ÿ
requires an equivalent amount of applied force to either manually open or close.
Ÿ
requires no more than 150N (15kg) of applied force to either manually open or close.
Ÿ
does not rise or fall more than 100mm when released at any point between fully open or fully closed positions.
Ÿ
does not rub on or incorrectly make contact with any supporting or surrounding structures
Ÿ
If the door is not a new installation, check the state of wear of all the components, repair or replace the defective or
Ÿ
worn parts and perform any other operations necessary.
The Wall Bracket carries ALL of the opening and closing thrust of the Opener and as such must be securely
Ÿ
fastened to a rigid, structural member of the garage wall or ceiling. It is entirely up to the installer to determine the
fixing method and the structural suitability of the fixing points.
TAIMEN T6
Irreversible electromechanical gearmotor
MAX 80W
600 N
90-125 mm/s manually adjustable
-20°C + 60°C
IP 20
2400 mm
10 sq. m.
30% (at 20°C)
A + C
%Fu =
x 100
A + C + P
TAIMEN T12
220/230V 50-60 Hz
24Vdc
MAX 140W
1200 N
Automatic
-20°C + 60°C
IP 20
2400 mm
15 sq.m.
30% (at 20°C)
on board
A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two openings
15
UK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taimen t12

Table of Contents