GiBiDi BL240 Instructions For Installation Manual

GiBiDi BL240 Instructions For Installation Manual

Electromechanical linear operator

Advertisement

BL240
BL240 - (15400)
Operatore elettromeccanico lineare
ISTRUZIONI PER L'INSTALLAZIONE
Electromechanical linear operator
INSTRUCTIONS FOR INSTALLATIONS
I
UK
F
D
P
NL
E
GR

Advertisement

Table of Contents
loading

Summary of Contents for GiBiDi BL240

  • Page 1 BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L’INSTALLAZIONE Electromechanical linear operator INSTRUCTIONS FOR INSTALLATIONS...
  • Page 2 BL240 9 1b BL240 - 24Vdc DESCRIZIONE CAVI / CABLES DETAILS Rosso / Red Positivo / Positive Nero / Black Negativo / Negative Blu / Blue FCA OPEN Marrone / Brown FCA COM Blu / Blue FCC CLOSE Marrone / Brown...
  • Page 3 BL240 740 mm 897 mm B ≥ 140 per β = 110° B > 60+d1 per β = 90° D ≥ 90 a1>60 β...
  • Page 4 BL240 E=60 100/120...
  • Page 5 BL240...
  • Page 6 BL240...
  • Page 7 BL240...
  • Page 8: Installation Warnings

    INTRODUCTION The BL240 operator for swing gates is an electromechanical device that transmits motion to the gate by means of a worm screw. It is locked when the motor is not running, and it is therefore not necessary to install locks for leafs up to 2 m.
  • Page 9: Electrical Equipment

    BL240 ELECTRICAL EQUIPMENT Electric system setup Set up the electric system as shown (1a - 1b) referring to the electric system regulations and other national regulations in force. Keep the mains power connections clearly separated from the service connections (photocells, sensitive frames, control devices, etc.).
  • Page 10: Technical Data

    BL240 TECHNICAL DATA Operator BL240 Type Irreversible electromechanical with worm screw Supply voltage 24 Vdc Power absorbed 100 W (~1000 N) Current absorbed 4 A (~1000 N) Electric motor 24 Vdc 3000 rpm Useful travel 320 mm Max thrust/traction force...
  • Page 11: Operator Installation

    BL240 Table A - for 100 mm column and 50 mm leaf thickness β 90° 90° 100° 110° OPERATOR INSTALLATION Preliminary checks: For proper functioning of the automated device, the existing or new gate structure must meet the following requirements:...
  • Page 12: Limit Switch Adjustment

    BL240 If the gate is in a material different from iron, make a plate of 5 mm thick with 4 holes. Weld the bracket in the centre of the plate and secure everything with through screws (12). 12- Unlock the operator (see unlocking device).
  • Page 13: Final Checks

    • That the power cable moves freely; • The gate assembly conforms to EN 12453 and EN 12445; • For further details and information on the reference standards, visit our site: www.gibidi.com MAINTENANCE Periodically check the gate structure, in particular: - Check functioning of the hinges;...
  • Page 14 Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the products: ELECTROMECHANICAL LINEAR OPERATORS BL240 Are in conformity with the following CEE Directives: • EMC Directive 2004/108/CE and subsequent amendments; and that the following harmonised standards have been applied: EN61000-6-1, EN61000-6-3 •...
  • Page 15 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: comm@gibidi.com Numero Verde: 800.290156 w w w . g i b i d i . c o m...

Table of Contents