TECHNICAL CHARACTERISTICS

Power supply
No. of motors
Flashlight
Photocell power supply
Electric lock
Operating temperature
Pause Time
Run time
Fixed pre-flashing
General
The electronic control unit code AS04330 and AS04340 for control of one or two 12 VDC motors for swing gates is in conformity with the Directives
in force.
Functions available: - step-by-step
- step-by-step with automatic reclosing (residential)
- condominium
- pedestrian opening with second remote control channel (only with RADIO MODULE code AU01780)
- water hammer
- deceleration
- automatic closing after freeing the photocells
Adjustments :
- run time
- pause time
- gate phase shift time
- amperometric thresholds
WARNINGS
A) Before proceeding with installation, fit a magnetothermal or differential switch with maximum capacity of 10A upstream of the system.
The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3 mm.
B) To prevent possible inter ference, differentiate and always keep the power cables (minimum cross-section 1.5 mm
signal cables which must be at least 0.5 mm
C) Make the connections referring to the following table and the attached silk-screen print. Be ver y careful to connect in series all the
devices that are connected to the same NC (normally closed) input and in parallel all the devices that share the same NO (normally open)
input.
Incorrect installation and improper use of the product may compromise the safety of the system.
D) All the material contained in the package must be kept out of reach of children, since they constitute a potential hazard.
E) The manufacturer declines all responsibility for proper functioning of the automated device if original Gi-Bi-Di components and accessories
suitable for the application are not used.
F) After installation always carefully check proper functioning of the system and the devices used.
Connections (Terminal Board Legend)
1
PHOTOCELL input (NC)
STOP input (NC). Causes a functional stop of the
2
motion (NOT A SAFETY STOP)
3
START input (NO)
4
COMMON for STOP-START-PHOTOCELLS
12 VDC output for power supply, max. 2 pairs of
5 - 6
photocells (6 = POSITIVE)
12 VDC output for ELECTRIC LOCK power supply
7 - 8
(max. 15 W)
9 - 10
12 VDC output for FLASHLIGHT ( max. 15 W )
(
*
) WARNING:
IF USING WITH BATTERY, THE "OPTIONAL CABLE" ACCESSORY SPECIFICALLY DESIGNED FOR RECHARGING IS REQUIRED.
CONNECTING A BATTERY WITHOUT THIS SPECIAL CABLE MAY CAUSE IRREPARABLE DAMAGE TO THE CONTROL UNIT.
230 VAC, single-phase, 50 /60 Hz
2 x 12 VDC 30W (code AS04330 )
2 x 12 VDC 60W (code AS04340)
12 VDC 15W max.
12 VDC 6W max. (2 pairs of photocells)
12 VDC 15W max.
-20 to +60°C
0 - 240 s
0 - 240 s
2 s
2
.
11 - 12
13 - 14
15
16
CN4 -
CN5
(
CN2-
CN3
F - N
English
Output
Motor 2
( 12 positive during opening )
Output
Motor 1 (= it opens for first) to be used for
pedestrian gate (14 positive during opening)
ANTENNA ground
ANTENNA signal
Input for 12 VDC BUFFER BATTERY (CN4 = positive)
*
)
12 VAC input (from transformer)
Power supply, 230 VAC, single-phase, 50/60 Hz
7
2
) separate from the