Electrical Equipment; Technical Data - GiBiDi SL 820 Instructions For Installation Manual

Electromechanical gearmotors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
SL

ELECTRICAL EQUIPMENT [1]

1- Gearmotor; 220-230V power supply, 3x1.5mm² cable (comply with the current standards)
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- Flashing light signaller 2x0.75mm² cable
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm Power supply line to the control unit
220-230V, 50-60Hz, 3x1.5 mm² cable (comply with the current standards).

TECHNICAL DATA

Operator
Type
Supply voltage
Power absorbed
Current absorbed
Thermal cuout
Pick-up capacitor
Max speed
Max torque
Operating temperature
Degree of protection
Max leaf weight
Operating frequency (%)
Type of oil / grease
Formula to calculate the
operating frequency
[28]
Irreversible electromechanical gearmotor
A + C
%Fu =
x 100
A + C + P
SL 820-830-840
220/230V 50-60Hz
MAX 350W
MAX 1.5A
140°C
10µF
0,16 m/s
20 Nm
-20°C + 60°C
IP 45
800 Kg
60% (a 20°C)
GBD PH-02
A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two openings
19