Technical Data; Preliminary Warnings - GiBiDi BL233 Instructions For Installation Manual

Electromechanical linear operator
Table of Contents

Advertisement

Available languages

Available languages

BL230-BL233

TECHNICAL DATA

Operator
Type
Supply voltage
Power absorbed
Current absorbed
Max power absorbed
Max current absorbed
Electric motor
Thermic
Breakaway capacitor
Max thrust / traction force
Operating temperature
Frequency of use
Effective travel
Protection class
Maximum gate length
Limit switches

PRELIMINARY WARNINGS

Make sure that the gate structure conforms with current standards and that gate movement is linear and
friction free.
Preliminary checks:
• Make sure that the gate structure is sufficiently sturdy.
In any case, the actuator must operate on a reinforced point on the gate.
• Make sure that the gates move manually without effort over their entire travel.
• Make sure that gate opening and closing locator stops are installed
• If the gate is not a new installation, check the wear status of the hinges and all components; repair or replace
defective or worn components.
The reliability and safety of the automation device are directly affected by the status of the gate structure.
BL230
non-reversible electromechanical with worm screw
220/230 V 50-60 Hz
150 W (~1000 N)
0.8 A (~1000 N)
300 W max
1.5 A max
4 poles 1400 rpm
140°C
12.5 m
3000 N (electronically adjustable)
-20°C +60°C
40% (~20°C)
380 mm
IP 44
3.5 m
2 limit switches (open / close)
[
]
1a .
UK
BL233
F
500 mm
5 m
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bl230

Table of Contents