Technical Data; Electrical Equipment - GiBiDi KUDA 150 Instructions For Installations

Electromechanical linear operator
Table of Contents

Advertisement

Available languages

Available languages

KUDA

TECHNICAL DATA

Operator
Type
Supply voltage
Power absorbed
Current absorbed
Electric motor
Useful travel
Max thrust/traction force
Maximum leaf length
Maximum leaf weight
Linear velocity
Operating temperature
Degree of protection
Frequency of use (%)
Encoder

ELECTRICAL EQUIPMENT

Electric system setup
Set up the electric system as shown in fig.1 referring to the electric system regulations and other national regulations
in force. Keep the mains power connections clearly separated from the service connections (photocells, sensitive
frames, control devices, etc.).
The main components are:
1- Antenna; screened coaxial cable
2- Electronic control unit container
3- Electric lock; 1 mm² 2-core (2x1) cable
4- Key selector; 0,5 mm² 3-core (3x0,5) cable
5- 24Vdc operators:
- 1,5 mm² 2-core (2x1,5) cable power supply WHITE = + YELLOW = -
for a cable length of 6 m max., over it's necessary increase the cable section.
-0,5mm² 3-core (3x0,5) encoder cable.
6- Omnipolar magnetothermal and differential switch with minimum contact opening of 3 mm
220-230V/50-60Hz control unit power line: min. 1,5 mm² 3-core cable (3x1,5)
(adhere to the regulations in force)
7- 24V flashing light; 0,75 mm² 2-core (2x0,75) cable
8- Connector blocks
9- Photocell transmitter; 0,5 mm² 2-core (2x0,5) cable
10- Photocell receiver; 0,5 mm² 4-core (4x0,5) cable
A- Opening mechanical end-stop.
B- Closing mechanical end-stop.
CAUTION: It is important that an omnipolar magnetothermal and differential switch with a
minimum contact opening of 3 mm be fitted upstream of the control unit.
KUDA 150
Irreversible electromechanical with worm screw
24 Vdc
100 W (~1000 N)
4 A (~1000 N) MAX
24 Vdc 2600 rpm
360 mm
1000 N
2 m
If fitted on blind/flush panel doors
it is mandatory to use an electric lock
150 Kg
20 mm/s
-20°C + 60°C
IP 44
intensive
Integrated into the motor
KUDA 200
400 mm
1500 N
2.5 m
200 Kg
11