Power Supply Connection - Beckhoff C5101 Installation And Operating Instructions Manual

19 inch rack mount industrial pc
Table of Contents

Advertisement

Supplied mains power unit
Current carrying capacity
of the 100-240 V power
supply unit
Socket at the PC housing
Power cords Europe
Power cords USA / Canada In the area USA / Canada the power supply cable must show the following
C5101

Power Supply Connection

The Industrial PC is fitted with a 100-240 V, 50-60 Hz full range power
supply unit (with the option of an uninterruptible power supply, UPS).
Output voltages from
the 100-240 V power
supply unit
+3,3 V
+5 V stand by
+5 V
-5 V
+12 V
-12 V
Mains Socket
A mains socket is located at the rear of the PC housing next to the main
switch in order to connect the power supply.
Power supply cords
In the area Europe you use the provided cable with inlet connector for non-
heating apparatus to connect the Industrial-PC to the power supply.
specifications according to the supply voltage:
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 5-15P/-20P
grounding-type attachment plug, other end in appliance coupler
or
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 6-15P/-20P
grounding-type attachment plug, other end in appliance coupler.
Current loading
maximum
16 A
2 A
25 A
0,3 A
13 A
0,8 A
Installation Instructions