Beckhoff C6640 Installation And Operating Instructions Manual

Beckhoff C6640 Installation And Operating Instructions Manual

Control cabinet industrial pc
Hide thumbs Also See for C6640:
Table of Contents

Advertisement

Installation and Operating instructions for
Control Cabinet Industrial PC
C6640, C6650
Version: 1.1
Date:
2010-04-08

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff C6640

  • Page 1 Installation and Operating instructions for Control Cabinet Industrial PC C6640, C6650 Version: 1.1 Date: 2010-04-08...
  • Page 3: Table Of Contents

    Mains Socket Power supply cords Power Supply Connection with 24 V power supply unit (optional) Beckhoff power supply technology Electrical Data Pin assignment of the connectors Pin assignment power supply Pin assignment external wiring Fitting the Cables...
  • Page 4 Beckhoff Support & Service Beckhoff branches and partner companies Beckhoff Headquarters Beckhoff Support Beckhoff Service Assembly dimensions C6640, Configuration with 100-240 V Power Supply C6640, Configuration with 24 V -Power Supply (optional) C6650, Configuration with 100-240 V Power Supply C6650, Configuration with 24 V...
  • Page 5: General Instructions

    © This documentation is copyrighted. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden. Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
  • Page 6: Basic Safety Measures

    If metal objects such as screws or tools fall onto operating circuit boards. • If connecting cables internal to the PC are removed or inserted during operation. • If plug-in cards are removed or inserted when the PC is switched C6640, C6650...
  • Page 7: Operator's Obligation To Exercise Diligence

    Read the operating Every user of the Industrial PC must have read these operating instructions instructions. Software knowledge Every user must be familiar with any of the functions of the software installed on the PC that he can reach. C6640, C6650...
  • Page 8: Product Description

    Product Description Product Description Appropriate Use The C6640 and C6650 Industrial PCs are designed for mounting in control cabinets for machine and plant engineering applications. Opening the Housing View of the C6650, configuration with 100-240 V power supply unlock key (1) The housing cover is locked by a latch.
  • Page 9 (2) Now the housing cover can be taken off completely, so providing access to the components. The reassembly of the cover takes place in reverse order. Ensure that the cover engages into the slides (2). C6640, C6650...
  • Page 10: Configuration With 100-240 V

    Order option Intel Intel Intel Intel Intel ® Celeron Pentium M Core™ Duo Core™ 2 Duo Core™ 2 Quad C6640-0000 1,5 GHz 1,8 GHz C6640-0010 2,0 GHz 2,16 GHz C6640-0020 2,53 GHz 2,26 GHz C6650-0010 2,0 GHz 2,16 GHz C6650-0020...
  • Page 11: Interfaces

    Product Description Interfaces Interfaces to the X103 X114 X110 X108 C6640, C6650 X107 X105 X111 X109 X115 X104 X113 X112 X106 X116 PS/2 connections PS/2 A PC keyboard can be connected to the upper PS/2 connector (X103), while the lower PS/2 connector (X104) allows a PS/2 mouse to be used.
  • Page 12: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. C6640, C6650...
  • Page 13: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The C6640 and C6650 Industrial PCs are designed for mounting in control cabinets for machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical data).
  • Page 14: Power Supply Connection With 100-240

    Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V, 10 A, Type SJT or Type SVT; one end terminates in NEMA 6-15P/-20P grounding-type attachment plug, other end in appliance coupler. C6640, C6650...
  • Page 15: Beckhoff Power Supply Technology

    However, over time this reduces the service life of the battery. The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery.
  • Page 16: Electrical Data

    Plug connectors with CAGE CLAMP connection X102 X101 Pin assignment power supply Pin assignment for X101 Function connecting the power Battery Pack (with USV) supply and the battery pack (optional) Power Supply C6640, C6650...
  • Page 17: Pin Assignment External Wiring

    4. Relieve the strain on the supply cable by fixing it in place with the cable clamp (part C) and fixing screws (part D). Applying the strain relief Fix the upper part (part B) of the strain relief housing by snapping it onto the lower part. C6640, C6650...
  • Page 18: Connecting Power Supply

    The maximum load is 2.0 A. • Once the PC has been de-energised via the UPS software, the UPS output is switched to 0 V. Any connected panel is thus switched off, and total discharge of the rechargeable battery is prevented. C6640, C6650...
  • Page 19: Wiring Diagram

    Wiring according to the wiring diagram (the circuit of PC_ON and Power- Status is symbolical): Wiring diagram power supply and external switch The battery pack can only be connected when the Industrial PC is provided with an integrated UPS (order option). Note C6640, C6650...
  • Page 20: Connecting Devices

    Fitting the Cable) into the Industrial PC's power supply socket. Then connect it to your external 24 V power supply. If a 24 V UPS is installed, the correct type of rechargeable battery must be used. Warning C6640, C6650...
  • Page 21: Operating Instructions

    If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices. C6640, C6650...
  • Page 22: Servicing And Maintenance

    Removing the fan Disconnect the supply cable from the motherboard. Therefor it can be necessary to remove the housing cover. After exchanging the fan cartridge the reassembly takes place in reverse order. C6640, C6650...
  • Page 23: Servicing

    The driver software comes with a detailed help function. System The help files can be called up either directly from the configuration register by clicking the Help button, or under via Start > Programs > Beckhoff > UPS software components. C6640, C6650...
  • Page 24: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service. The Industrial PC does not boot CD in the drive. Remove CD and press any fully key.
  • Page 25: Beckhoff Support & Service

    Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com You will also find further documentation for Beckhoff components there.
  • Page 26: Assembly Dimensions

    Assembly dimensions Assembly dimensions The following pages show diagrams of the Industrial PC, with dimensions in mm. C6640, Configuration with 100-240 V Power Supply The assembly of the unit must take place with the orientation diagrammed here. Warning C6640, C6650...
  • Page 27: C6640, Configuration With 24 V

    Assembly dimensions C6640, Configuration with 24 V -Power Supply (optional) The assembly of the unit must take place with the orientation diagrammed here. Warning C6640, C6650...
  • Page 28 Assembly dimensions C6650, Configuration with 100-240 V Power Supply The assembly of the unit must take place with the orientation diagrammed here. Warning C6640, C6650...
  • Page 29 Assembly dimensions C6650, Configuration with 24 V -Power Supply (optional) The assembly of the unit must take place with the orientation diagrammed here. Warning C6640, C6650...
  • Page 30: Appendix

    Power supply Supply voltage: 100-240 V 50-60 Hz 100-240 V power pack Power consumption: C6640: 65 W (for the basic version) C6650: 90 W (for the basic version) Power supply Supply voltage: 22 – 30 V 24 V power pack...

This manual is also suitable for:

C6650

Table of Contents