GROUND LINE
Disconnect the starter relay switch 4P (Red) connector
[1
].
Check for continuity between the Green/red wire of the
wire harness side (ground line) and ground.
If there is continuity when the transmission is in neutral
or when the clutch is disengaged and the sidestand is
retracted, the ground circuit of the relay coil is normal.
(In neutral
,
there is a slight resistance due to the diode.)
STARTER RELAY INPUT VOLTAGE
Connect the starter relay switch 4P (Red) connector [1]
.
Turn the ignition switch ON and engine stop switch "O''.
Measure the voltage between the Yellow/red (+) wire
terminal at the starter relay switch 4P (Red) connector
and ground (-)
.
If the battery voltage appears only when the starter
switch is pushed with the ignition switch ON and engine
stop switch
"O",
the starter relay input voltage is normal.
OPERATION CHECK
Remove the starter relay switch (page
6-9).
Connect a 12 V battery to the starter relay switch as
shown.
There should be continuity between the cable terminals
when the battery is connected, and no continuity when
the battery is disconnected.
REMOVAL/INSTALLATION
Remove the single seat (page 2-5).
Release the rubber cover [1].
Disconnect the starter relay switch 4P (Red) connector
[2].
Remove the bolts [3] and cables [4]
.
Remove the starter relay switch [5] from the stays with
the shock
rubber.
Remove the starter relay switch from the shock rubber.
Installation is in the reverse order of removal.