Download Print this page

Honda CBR300RA Service Manual page 190

Hide thumbs Also See for CBR300RA:

Advertisement

FAN CONTROL RELAY
INSPECTION
Remove the left middle cowl (page 2-7).
Remove the relay cover.
Remove the fan control relay
[1 ].
Connect a ohmmeter to the fan control relay [1]
terminals
.
Connect a 12 V battery to the fan control relay terminals
as shown.
There should be continuity only when 12 V battery is
connected.
If there is no continuity only
when
the 12 V battery is
connected,
replace the fan control relay.
WATER PIPE
REMOVAL/INSTALLATION
Drain the coolant
(page
8-5).
Remove the bolts [1] and water pipe [2].
Remove the 0-rings [1] from the water pipe.
Install new 0-rings to the
water
pipe.
Installation is in the reverse order
of
removal.
[1]
[1]
Fill the system with the recommended
coolant
(page
8-
·
1 •
6).
COOLING SYSTEM
- - - - B l / W
Br/R
81/W
Bu
8-15

Advertisement