After replacing a cylinder or after making a
gas connection, perform a leak test
Stage1
1. Turn the gas OFF
2. Using soapy water applied with a sponge, or with a
brush, cover all of the gas joints with a liberal
amount of suds.
Stage 2
1. Turn the gas ON
2. Adjust the pressure to between 2.7- 3.0 bar
3. Inspect the joint for leaks.
4. If any bubbles appear, the joint will need to
be resealed and tested again.
802149UK Celsius residential - Installation instructions -Jan 2016 v2.03
CO
regulator
2
ON - OFF knob
Green indicator
Note
When removing hose, take care not to
lose plastic olive from the nut.
Leak test
Faulty seal joint