Installation instructions
Zip HydroTap G4
®
Filtered chilled and sparkling drinking water for commercial kitchens and tea rooms.
VENTILATION IS
ESSENTIAL
Affix model number label
!
here
804050UK
READ
SECTION 2 'VENTILATION'
READ BEFORE YOU START
804050UK G4 Commercial chilled and sparkling installation instructions - Sept. 2016 - v3.02
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for Zip Elite HydroTap G4

  • Page 1 Installation instructions Zip HydroTap G4 ® Filtered chilled and sparkling drinking water for commercial kitchens and tea rooms. VENTILATION IS ESSENTIAL Affix model number label here 804050UK READ SECTION 2 'VENTILATION' READ BEFORE YOU START 804050UK G4 Commercial chilled and sparkling installation instructions - Sept. 2016 - v3.02...
  • Page 2 Tap options The G4 series offers a range of interchangeable taps to suit the customer's needs. Elite HydroTap G4 range ® These standalone taps are directly compatible with the G4 Command-Centre Classic HydroTap G4 range ® Arc / Cube HydroTap G4 range ®...
  • Page 3: Table Of Contents

    Index HydroTap G4 specifications ® Installation check list ........................4 General product features ......................5 Important safety instructions ......................6 Warnings ............................7 Major components and accessories ..................... 8 Technical specification ......................... 9 Before installation and site requirements ..................10 Installation instructions Step 1 - Measure and cut all the tap holes, fit the taps : Refer to 803341UK Tap installation...
  • Page 4: Installation Checklist

    Installation checklist Before installation • Read the instructions and check if there is adequate space to mount all of the components. • Note Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. • Check the mains water pressure is within min / max requirements (see page 9). • Check the water quality to determine if extra filtration will be required.
  • Page 5: General Product Features

    ® The Zip HydroTap G4 is an electronically controlled, filtered, chilled and sparkling water, drinking system ® for kitchens and tea rooms. The Zip HydroTap G4 Command-Centre is an under counter drinking water ® appliance with a dispensing tap mounted on a sink or worktop, which has been designed for commercial applications.
  • Page 6: Important Safety Instructions

    Important safety instructions This manual contains important safety and installation instructions for the Zip HydroTap ® Please read all warnings, installation requirements and installation instructions before installing any Zip HydroTap G4. This system must be installed in accordance with water supply byelaws, ®...
  • Page 7: Warnings

    • Do not expose the Zip HydroTap G4 to the elements of nature. ® • Due to the process of continuous improvement, Zip reserves the right to change details mentioned in this manual, without notice. Visit www.zipwater.com/uk to ensure you have the latest copy.
  • Page 8: Major Components And Accessories

    SPIDER BCH240/175G4 required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be guide required. (One GPO is for the Zip HydroTap and the other for the Booster heater). CLAMP NOTE: feed each of the three tubes and AV160/125G4 NOTE: Check the cable lengths and outlet positions before proceeding.
  • Page 9: Technical Specification

    Technical specifications Commercial Chilled and sparkling HydroTap G4 range ® HydroTap ® Chilled, sparkling and filtered. Elite Classic Arc / Cube HydroTap s with mixer taps ® Chilled, sparkling, filtered and mixed hot & cold. Celsius Capacity Capacity Power Boost *Dry boiling Unit Dimensions...
  • Page 10: Before Installation And Site Requirements

    • Sufficient space in the cupboard to install the Command-Centre other components in accordance with these installation instructions. See technical specification, page 9 for dimensions. • For Zip HydroTap G4 Chilled and sparkling only models, 1 x 220-240V AC ®...
  • Page 11: Section 1 - Ventilation

    Section 1 Ventilation 1.1 Ventilation for all models • The clearance envelope dimensions stated in the specification sheets and installation instructions must be observed. • Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed 1.2 Preferred ventilation arrangements for CS models The ducted vent kit supplied with the Command-Centre exhausting through the kick-space should be used,...
  • Page 12 Ventilation 1.3 Alternative arrangement (Dual fan kit) In situations where the preferred arrangement cannot be used or will not work effectively e.g. • Single cupboard where the 100mm grille spacing cannot be achieved. • Where there are openings in the back of the cupboard allowing exhaust air to recirculate into the cupboard space.
  • Page 13: Cylinder

    Section 2 Cylinder STORAGE WARNING WARNING! The cylinder ( containing 1kg of CO ) should be installed in a well ventilated area of area no less than 38m If more than 1 gas cylinder containing 1kg of CO is present within the same location, the recommended ventilation area should be in proportion to the number of gas cylinders stored in that location.
  • Page 14: Section 3 - Command-Centre Tm Installation

    Regulator Note When removing hose, take care not to lose plastic olive from the fitting. Leak Test After replacing a cylinder or after making a gas connection, perform a leak test to check for gas leaks between regulator and cylinder, and between regulator and braided hose.
  • Page 15: Chilled And Sparkling Hydrotap ® G4 Models

    Installation instructions 3.2 Chilled and sparkling HydroTap G4 models Refer to 803341UK Tap installation ® instructions (for Arc / Cube also refer to the tube kit assembly instructions) supplied with the tap. Elite Classic Arc / Cube MAINS STILL SPARKLING POWER OUTLET OUTLET...
  • Page 16: Chilled And Sparkling Hydrotap ® G4 Models Together With Mixed Hot Cold Water

    Installation instructions 3.3 Chilled, sparkling and mixed hot & cold Celsius Arc Celsius Cube MAINS STILL SPARKLING POWER OUTLET OUTLET CABLE Note Mains hose length is 750mm. Electrical power cable length is 3.0m nom. Position the Command-Centre according to the hose and cable lengths supplied.
  • Page 17: Section 4 - Commissioning

    Section 4 Commissioning The HydroTap G4 is now ready to be commissioned. ® • Turn on the power, gas and water and check for any leaks. • Familiarise yourself with the operation of the HydroTap G4 in preparation for use (see User manual). ®...
  • Page 18 Commissioning • Press [START] / [STOP] button to start and stop the filter flush. • Open the flush stop cock. • Allow at least 10 litres of water to flush through the filter. • Once the filter flush is finished, Close the stop cock then press [STOP] to end filter flush mode.
  • Page 19: Trouble Shooting

    Internal fault Call Zip Service Call an electrician, a plumber, or Zip on 0345 6 005 005 for assistance, service, spare parts or enquiries. End of life disposal The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste.