Allen-Bradley PowerFlex 755T User Manual page 35

Powerflex 750-series drives with totalforce control built-in ethernet/ip adapter
Hide thumbs Also See for PowerFlex 755T:
Table of Contents

Advertisement

1. Depending on the type of server (BOOTP or DHCP) being used, set
0:300 - [Net Addr Sel] to either '2' (BOOTP) or '3' (DHCP)
respectively.
Stopped
0.00 Hz
ESC
2. Make note of the Ethernet Address (MAC) of the interface hardware,
which is used in
There are two ways to find the media access control (MAC) address:
• Remove the drive cover and locate the hardware Ethernet Address
label on the main control board of the drive
Figure 7 - Location of the Interface Hardware Address Label
Drive Control Pod
• Use the HIM to scroll to drive Port 0 and access the built-in
EtherNet/IP interface DIAGNOSTIC folder screen. Then scroll to
Diagnostic Items 43...48 (HW Addr 1...6) to view the hardware
Ethernet Address (MAC) of the interface. Finally, convert these
decimal values to hex values.
Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017
With drive firmware 1.xxx or later
AUTO
Value
F
Edit Net Addr Sel
1
2
1 << 3
ENTER
3
step
7.
Ethernet
Address
(MAC)
Label
Location
Front View - Main Control Board
Configure the Interface
Chapter 2
Setting
Parameters
BOOTP
DHCP (default)
(Figure
7).
Ethernet Connectors
37