Set the IP Address
1. Verify 0:300 - [Net Addr Sel] is set to '1' (Parameters).
2. Set the value of 0:302 - [IP Addr Cfg 1] ... 305 - [IP Addr Cfg 4] to a
unique IP address.
Stopped
0.00 Hz
Edit IP Addr Cfg 1
0 << 255
ESC
Set the Subnet Mask
1. Verify 0:300 - [Net Addr Sel] is set to '1' (Parameters).
2. Set the value of 0:306 - [Subnet Cfg 1] ... 309 - [Subnet Cfg 4] to the
desired value for the subnet mask.
Stopped
0.00 Hz
Edit Subnet Cfg 1
0 << 255
ESC
• The PowerFlex 755T subnet mask cannot be 0.0.0.0.
• The PowerFlex 755T gateway address can be 0.0.0.0. If the gateway
address is 0.0.0.0, the PowerFlex 755T can only communicate with
devices on the same subnet as the drive. It is not able to communicate
with devices on other subnets.
• If the PowerFlex 755T gateway address is not set to 0.0.0.0, then it must
be set to an address that is on the same subnet as the drive's IP address.
Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017
Default = 0.0.0.0
AUTO
F
0
ENTER
Default = 0.0.0.0
AUTO
F
0
ENTER
Configure the Interface
Chapter 2
255.255.255.255
[IP Addr Cfg 1]
[IP Addr Cfg 2]
[IP Addr Cfg 3]
[IP Addr Cfg 4]
255.255.255.255
[Subnet Cfg 1]
[Subnet Cfg 2]
[Subnet Cfg 3]
[Subnet Cfg 4]
35