No.
U120 Main shaft reference angle correction
The main shaft reference signal angle (0 degree) is corrected with the value
set using this memory switch.
U121 Upper stop position angle correction
The position at which the sewing machine stops with its needle up is
corrected.
U122 Lower stop position angle correction
The position at which the sewing machine stops with its needle down is
corrected.
U182 Sewing counter stopping function
0: The sewing machine does not stop even when the sewing counter
completes counting.
1: When the counter completes counting, the sewing machine start after
thread trimming is prohibited.
* Note that the prohibition function is disabled in the case the initial value of
counter is 0 (zero).
U183 Number of times of thread trimming for sewing counter
U280 Number of condensation stitches at the end of sewing before shorter-
thread remaining type thread trimmer operates
When the shorter-thread remaining function is placed in ON, this memory
switch is used for setting the number of condensation stitches to be sewn
before thread trimming.
U281 Pitch of condensation stitches at the sewing end before shorter-thread
remaining type thread trimmer operates
When the shorter-thread remaining function is placed in ON, this memory
switch is used for setting the stitch pitch of condensation stitches to be sewn
before thread trimming.
U286 Sewing speed during thread presser operation
This memory switch is used for setting the speed to be employed when the
thread presser operates.
U288 Thread presser ON angle
This memory switch is used for setting the angle at which the thread presser
is turned ON at the start of sewing.
U289 Thread presser OFF angle
This memory switch is used for setting the angle at which the thread presser
is turned OFF at the start of sewing.
U290 AK operating time when the thread presser operates
The time to turn ON the AK device that operates when the thread presser
operates.
U292 Soft-start resetting angel when the thread presser operates
This memory switch is used for setting the angle at which the soft-start is reset.
* The setting is enabled when the thread presser operates.
U293 Sewing speed resetting angle when the thread presser operates
This memory switch is used for setting the angle at which the sewing speed
employed when the thread presser operates is reset.
* The setting is enabled when the thread presser operates.
U294 Thread-presser initial suction time
Item
– 65 –
Setting range
Unit
-60 to 60
Degree
-15 to 15
Degree
-15 to 15
Degree
0 to 1
1 to 20
1 to 9
Stitch
0 to 2.5
0.05 mm
100 to 3000
sti/min
180 to 290
Degree
210 to 359
Degree
0 to 50
ms
180 to 900
Degree
0 to 720
Degree
4 to 10
ms