Connection of the
The inputs/outputs are connected via ribbon cables (max. 3 m length). The
inputs/outputs
following 34-way terminal strip converters can be used for this purpose:
see References:
Terminal strip converter without LED:
Terminal strip converter with LED red:
Terminal strip converter with LED green: 6FC9302-2BB01
Assignment of the ribbon cable is compatible with the I/O modules (logic
modules) of the SINUMERIK 810.
Meaning
The module status of the single I/O module is indicated via two LEDs.
of the LEDs
LED green:
LED red:
X402
Connecting the outputs
outputs 0-31
Connector name:
Connector type:
Length of the ribbon cable:
Note
The outputs must be protected externally against voltage surges by inductive
loads. (free-wheeling diodes, RC elements, . . .)
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
5 V Power OK
Group error
1
Not
assigned
3
O
OUT0 0
5
O
OUT0 2
7
O
OUT0 4
9
O
OUT0 6
11
O
OUT1 0
13
O
OUT1 2
15
O
OUT1 4
17
O
OUT1 6
19
O
OUT2 0
21
O
OUT2 2
23
O
OUT2 4
25
O
OUT2 6
27
O
OUT3 0
29
O
OUT3 2
31
O
OUT3 4
33
O
OUT3 6
6 I/O Modules
6.1 Single I/O module
Catalog NCZ
6FC9302-2AA
6FC9302-2AB (0.5A)
6FC9302-2AL (2 A)
X402 OUTPUT 0–31
34-way DIN ribbon cable connection
Max. 3 m to the terminal strip converter
2
Not
assigned
4
OUT0 1
6
OUT0 3
8
OUT0 5
10
OUT0 7
12
OUT1 1
14
OUT1 3
16
OUT1 5
18
OUT1 7
20
OUT2 1
22
OUT2 3
24
OUT2 5
26
OUT2 7
28
OUT3 1
30
OUT3 3
32
OUT3 5
34
OUT3 7
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
6-87