8 DMP Compact Modules
8.5 DMP compact module 1I NC analog (6FC5211-0AA10-0AA0)
Table 8-8
Number of inputs
Galvanic isolation
Power supply V
Input voltage
Current consumption (24 V)
Connection of signal generators
Digital representation of the input signal
Total error over temperature range 0 to 55
error
Length of cables (shielded)
Weight
8-108
Technical data DMP compact module 1I NC analog
– Rated value
LOAD
– Perm. range
– Ripple
– Rated range
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
1 analog input
Yes
24 V DC
20.4 V to 28.8 V
3.6 Vpp
"10 V
85 mA
see below
11 bits + sign
"0.6 %
C including zero
max.
30 m
approx. 160 g
Copyright © Siemens AG 2006