Technical data
Table 6-1
Power supply for LOGIC (X1) and POWER (X5)
Current consumption
Power loss
Inputs
Outputs
Overtemperature protection
Coincidence factor
Total of all rated currents each within group of 0.5 A
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
Technical data of the single I/O module
– rated value
– perm. range
– ripple
– polarity reversal protection
– fuse-protection
– LOGIC
– POWER
– LOGIC
– POWER
Number of inputs
Signal level for signal "0"
Signal level for signal "1"
Isolation
Input current 1-signal
p
g
Input current 0-signal
Delay time T
PHL
Delay time T
PLH
Voltage strength
Cable length terminal block
Number of outputs
Signal level for signal "0"
Signal level for signal "1"
Isolation
Short-circuit-proof
Max. output current
Switching frequency
Voltage strength
Cable length terminal block
6 I/O Modules
6.1 Single I/O module
24 V DC
18.5 ... 30.2 V
3.6 Vpp
yes
LOGIC: 1 A/250 V
POWER: no
Type: 0.3 A, max. 1 A
max: 12 A
Type: 7.2 VA, max. 30.2 VA
max. 362 VA
64 digital inputs
–3 V to + 5 V
+ 15 V to + 30 V
yes (optocoupler)
2 – 15 mA, type: 6 mA
, yp
–9 mA to 1 mA
0.5 to 3 ms
0.5 to 3 ms
2 kV
max. 3 m
32 digital outputs
open
U
– 0.5 V
Power
yes (optocoupler)
yes
resistive: 0.6 A
inductive: 0.6 A
Lamp: 6 W
ohmic load: 100 Hz
inductive load: 2 Hz
Lamp load: 11 Hz
2 kV
max. 3 m
Block specific
75 %
6-85