8 DMP Compact Modules
8.1 DMP compact module 16I (6FC5111-0CA01-0AA0)
S
Interfaces
S
S
S
Display elements
16 LEDs as a status display for the logical states of the inputs.
LEDs lit:
Table 8-2
Number of inputs
Galvanic isolation
Power supply V
Input voltage
Input current for signal "1"
Delay time
Delay time
Length for cables
Weight
8-98
A 30-pole connector X1 for connection to the NCU terminal block.
Two 10x terminals X2 and X3 (Phoenix, Type MC1.5/10-ST-3.81 GREY,
order no. for X3 and X2: 18 28 171) for connecting the 16 inputs and the
load power supply.
The terminals are pluggable and can be mechanically coded by the
customer.
The 24 V terminal P is not used
Input on.
Technical data of DMP compact module 16I
LOAD
– Rated value
– Perm. range
– Ripple
– Rated value
– For signal "0"
– For signal "1"
for tp
for tp
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
16 digital inputs
Yes
24 V DC
20.4 V to 28.8 V
3.6 Vpp
24 V DC
–3 to +5 V
+13 V to +33 V
+ 2 mA to + 5 mA
tp
= type 1 ms
LH
LH
tp
= type 1 ms
HL
HL
max. 30 m
about 125 g
Copyright © Siemens AG 2006