CHAPTER 5: SETTINGS
Operand type
Operand syntax
ELEMENT:
BUS 1 OP
Bus differential
BUS 1 DPO
BUS 1 BIASED OP A
BUS 1 BIASED OP B
BUS 1 BIASED OP C
BUS 1 BIASED PKP A
BUS 1 BIASED PKP B
BUS 1 BIASED PKP C
BUS 1 UNBIASED OP A
BUS 1 UNBIASED OP B
BUS 1 UNBIASED OP C
BUS 1 BIASED DPO A
BUS 1 BIASED DPO B
BUS 1 BIASED DPO C
BUS 1 UNBIASED DPO A
BUS 1 UNBIASED DPO B
BUS 1 UNBIASED DPO C
BUS 1 DIR A
BUS 1 DIR B
BUS 1 DIR C
BUS 1 SAT A
BUS 1 SAT B
BUS 1 SAT C
BUS 2
ELEMENT:
CT TROUBLE1 OP
CT trouble
CT TROUBLE1 OP A
CT TROUBLE1 OP B
CT TROUBLE1 OP C
CT TROUBLE 2
ELEMENT:
Counter 1 HI
Digital counters
Counter 1 EQL
Counter 1 LO
Counter 2 to 8
ELEMENT:
Dig Element 1 PKP
Digital elements
Dig Element 1 OP
Dig Element 1 DPO
Dig Element 2 to 48
ELEMENT:
FxE 1 PKP
FlexElements
FxE 1 OP
FxE 1 DPO
FxE 2 to 8
ELEMENT:
GROUND IOC1 PKP
Ground
GROUND IOC1 OP
instantaneous
GROUND IOC1 DPO
overcurrent
GROUND IOC2 to 6
ELEMENT:
GROUND TOC1 PKP
Ground time
GROUND TOC1 OP
overcurrent
GROUND TOC1 DPO
GROUND TOC2 to 6
ELEMENT:
LATCH 1 ON
Non-volatile latches
LATCH 1 OFF
LATCH 2 to 16
ELEMENT:
NEUTRAL IOC1 PKP
Neutral
NEUTRAL IOC1 OP
instantaneous
NEUTRAL IOC1 DPO
overcurrent
NEUTRAL IOC2 to 6
ELEMENT:
NEUTRAL OV1 PKP
Neutral overvoltage
NEUTRAL OV1 DPO
NEUTRAL OV1 OP
B30 BUS DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
Operand description
At least one phase of the bus differential characteristic has operated
At least one phase of the bus differential characteristic has dropped out
Phase A biased differential function has operated
Phase B biased differential function has operated
Phase C biased differential function has operated
Phase A biased differential function has picked up
Phase B biased differential function has picked up
Phase C biased differential function has picked up
Phase A unbiased differential function has operated
Phase B unbiased differential function has operated
Phase C unbiased differential function has operated
Phase A biased differential function has dropped out
Phase B biased differential function has dropped out
Phase C biased differential function has dropped out
Phase A unbiased differential function has dropped out
Phase B unbiased differential function has dropped out
Phase C unbiased differential function has dropped out
Phase A directional principle has picked up
Phase B directional principle has picked up
Phase C directional principle has picked up
CT saturation is detected in phase A
CT saturation is detected in phase B
CT saturation is detected in phase C
Same set of operands as shown for BUS 1
At least one phase of CT Trouble Zone 1 is operated
Phase A of CT trouble zone 1 has operated
Phase B of CT trouble zone 1 has operated
Phase C of CT trouble zone 1 has operated
Same set of operands as shown for CT TROUBLE 1
Digital counter 1 output is 'more than' comparison value
Digital counter 1 output is 'equal to' comparison value
Digital counter 1 output is 'less than' comparison value
Same set of operands as shown for Counter 1
Digital Element 1 is picked up
Digital Element 1 is operated
Digital Element 1 is dropped out
Same set of operands as shown for Dig Element 1
FlexElement 1 has picked up
FlexElement 1 has operated
FlexElement 1 has dropped out
Same set of operands as shown for FxE 1
Ground instantaneous overcurrent 1 has picked up
Ground instantaneous overcurrent 1 has operated
Ground instantaneous overcurrent 1 has dropped out
Same set of operands as shown for GROUND IOC 1
Ground time overcurrent 1 has picked up
Ground time overcurrent 1 has operated
Ground time overcurrent 1 has dropped out
Same set of operands as shown for GROUND TOC1
Non-volatile latch 1 is ON (Logic = 1)
Non-volatile latch 1 is OFF (Logic = 0)
Same set of operands as shown for LATCH 1
Neutral instantaneous overcurrent 1 has picked up
Neutral instantaneous overcurrent 1 has operated
Neutral instantaneous overcurrent 1 has dropped out
Same set of operands as shown for NEUTRAL IOC1
Neutral overvoltage element 1 has picked up
Neutral overvoltage element 1 has dropped out
Neutral overvoltage element 1 has operated
FLEXLOGIC
5
5-171