GE B30 Instruction Manual page 24

Bus differential system
Hide thumbs Also See for B30:
Table of Contents

Advertisement

ORDER CODES
B30
- * **
BASE UNIT
B30
|
|
POWER SUPPLY
(redundant supply must
be same type as main supply)
ENHANCED DIAGNOSTICS CT/VT DSP
(requires all DSP to be enhanced
diagnostic)
CONTACT INPUTS/OUTPUTS
2
TRANSDUCER INPUTS/OUTPUTS
(select a maximum of 3 per unit)
INTER-RELAY COMMUNICATIONS
(select a maximum of 1 per unit)
Table 2-5: B30 order codes for reduced-size vertical units
B30
- *
BASE UNIT
B30
|
CPU
T |
U |
V |
W |
SOFTWARE OPTIONS
2-10
- * *
* - F **
- H **
- L **
| |
|
|
|
|
H
|
|
|
H
|
|
|
L
|
|
|
L
|
|
|
|
|
XX
8L
|
8L
8M
|
8M
8N
|
8N
8R
|
8R
XX
XX
4A
4A
4B
4B
4C
4C
4D
4D
4L
4L
67
67
6A
6A
6B
6B
6C
6C
6D
6D
6E
6E
6F
6F
6G
6G
6H
6H
6K
6K
6L
6L
6M
6M
6N
6N
6P
6P
6R
6R
6S
6S
6T
6T
6U
6U
6V
6V
6W
6W
6X
6X
5A
5A
5C
5C
5D
5D
5E
5E
5F
5F
**
- * *
* - F **
- H **
- L **
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
00
| |
|
|
|
|
01
| |
|
|
|
|
03
| |
|
|
|
|
04
| |
|
|
|
|
A0
| |
|
|
|
|
- N **
- S **
- U **
- W/X **
Full Size Horizontal Mount
|
|
|
|
Base Unit
|
|
|
|
125 / 250 V AC/DC power supply
|
|
|
SH
125 / 250 V AC/DC with redundant 125 / 250 V AC/DC power supply
|
|
|
|
24 to 48 V (DC only) power supply
|
|
|
SL
24 to 48 V (DC only) with redundant 24 to 48 V DC power supply
|
XX
|
|
None (slots L and S only)
|
8L
|
|
Standard 4CT/4VT with enhanced diagnostics
|
8M
|
|
Sensitive ground 4CT/4VT with enhanced diagnostics
|
8N
|
|
Standard 8CT with enhanced diagnostics
|
8R
|
|
Sensitive ground 8CT with enhanced diagnostics
XX
XX
XX
|
No module
4A
4A
4A
|
4 Solid-State (no monitoring) MOSFET outputs
4B
4B
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
4D
|
16 Contact inputs with Auto-Burnishing (maximum of three modules within
a case)
4L
4L
4L
|
14 Form-A (no monitoring) Latching outputs
67
67
67
|
8 Form-A (no monitoring) outputs
6A
6A
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact
inputs
6B
6B
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact
inputs
6C
6C
6C
|
8 Form-C outputs
6D
6D
6D
|
16 Contact inputs
6E
6E
6E
|
4 Form-C outputs, 8 contact inputs
6F
6F
6F
|
8 Fast Form-C outputs
6G
6G
6G
|
4 Form-A (voltage with optional current) outputs, 8 contact inputs
6H
6H
6H
|
6 Form-A (voltage with optional current) outputs, 4 contact inputs
6K
6K
6K
|
4 Form-C and 4 Fast Form-C outputs
6L
6L
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact
inputs
6M
6M
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact
inputs
6N
6N
6N
|
4 Form-A (current with optional voltage) outputs, 8 contact inputs
6P
6P
6P
|
6 Form-A (current with optional voltage) outputs, 4 contact inputs
6R
6R
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
6S
6S
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
6T
6T
6T
|
4 Form-A (no monitoring) outputs, 8 contact inputs
6U
6U
6U
|
6 Form-A (no monitoring) outputs, 4 contact inputs
6V
6V
6V
|
2 Form-A outputs, 1 Form-C output, 1 Form-A latching output, 8 contact
inputs
6W
6W
6W
|
30 Contact inputs - pin terminals (max 4 modules)
6X
6X
6X
|
18 Form-A (no monitoring) outputs - pin terminals (max 4 modules)
5A
5A
5A
|
4 DCmA inputs, 4 DCmA outputs (only one 5A or 5D module is allowed)
5C
5C
5C
|
8 RTD inputs
5D
5D
5D
|
4 RTD inputs, 4 DCmA outputs (only one 5A or 5D module is allowed)
5E
5E
5E
|
4 RTD inputs, 4 DCmA inputs
5F
5F
5F
|
8 DCmA inputs
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-
mode, Laser
2J
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-
mode, Laser
72
1550 nm, single-mode, Laser, 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
7Q Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W RS422, 2 Channels
- N **
- R **
Reduced Size Vertical Mount
|
|
Base Unit
|
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
|
|
RS485 with 1 100Base-TX Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
|
RS485 with 3 100Base-TX Ethernet, SFP with RJ-45
|
|
RS485 with 2 100Base-FX Ethernet, multimode ST + 10/100Base-TX Ethernet, RJ-45
|
|
No software options
|
|
Ethernet Global Data (EGD) protocol
|
|
IEC 61850 protocol
|
|
IEC 61850 and Ethernet Global Data (EGD) protocols
|
|
CyberSentry Lvl 1
B30 BUS DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
CHAPTER 2: PRODUCT DESCRIPTION

Advertisement

Table of Contents
loading

Table of Contents