ZTP Data Time
This option sets the pause time in the data stream that the ZTP requires
before moving the form to the tear bar once a print job is completed. The
values range from .5 to 5 seconds. The default is .5 seconds.
ZTP Wait Time
This option sets the minimum amount of time that the form stays at the tear
bar. This allows you time to remove the form before the form is retracted to
print the next form. The adjustable values range from 500 to 5000
milliseconds in increments of 500 milliseconds. The default value is 2
seconds.
ZTP Platen Open
This option allows the user to have the platen open whenever forms are
reversed. Enabled is the default, used for most papers and labels. The feature
can be disabled as required by some multi-part forms.

CONFIG. CONTROL

The CONFIG. CONTROL menu allows you to control your printer's
configurations according to the specifications necessary for your print jobs.
CONFIG.
CONTROL
(from page 50)
Load
Config.
Factory*
1*
1-8
2-8
Name
Reset Cfg
Configs
1-8
1*
2-8
All
Load Config.
The printer can store numerous configurations in memory. This parameter
allows you to select and load a specific configuration.
Save
Print
Config.
Config.
Current Short*
1*
Current Full
2-8
Factory
Power-Up
All
1-8
Auto
Names
Save
Enable*
Disable