Centronics (Parallel) Submenu - Printronix H-SERIES P7000 User Manual

P7000 h-series
Hide thumbs Also See for H-SERIES P7000:
Table of Contents

Advertisement

Chapter
4
HOST INTERFACE

Centronics (Parallel) Submenu

Centronics
(from page 59)
Data Bit 8
PI Ignored
Enable*
Enable*
Disable
Disable
Prime
TOF Action
Signal
Enable*
Reset*
Disable
Do Nothing
Data Bit 8
Enable (default). Allows access to the extended ASCII character set.
Disable. The printer interprets bit 8 of each incoming data character as a
zero, regardless of its actual setting.
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper motion.
Enable (default). Ignores the PI signal and treats the data as characters
or control codes.
Disable. Causes the printer to interpret the eight data lines as VFU
commands when the PI signal is true.
Data Polarity
The Data Polarity parameter must be set to match the data polarity of your
host computer.
Standard (default). Does not expect the host computer to invert the data.
Inverted. Expects the data received on the data lines from the host
computer to be inverted. Ones become zeros, and vice versa.
62
Data Polarity
Resp.
Polarity
Standard*
Standard*
Inverted
Inverted
Buffer Size
Auto Trickle
in K
1
Disable*
2
Enable
4
8
16
32
64*
128
256
* = Factory Default
Busy on
Latch Data
Strobe
On
Enable*
Leading*
Disable
Trailing
Trickle Time
1/4 sec*
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off

Hide quick links: