Huawei AR530&AR550 Series Industrial Switch Routers
Configuration Guide - Ethernet Switching
Figure 9-5 Local bridging network diagram
A bridge group is created on Router A. Ethernet 2/0/1 in LAN 1 and Ethernet 2/0/2 in LAN 2
are added to the bridge group. In this manner, LAN 1 and LAN 2 are bridged and can
communicate with each other at the link layer.
After local bridging is configured, the bridge group configured for the transparent bridge is able
to:
l
l
l
l
l
9.2.3 Remote Bridging
If LANs in different geographical locations need to communicate with each other at the link
layer, remote bridging can be used to bridge the LANs.
Issue 01 (2014-11-30)
PC 3
PC 4
LAN1
Eth2/0/1
RouterA
Eth2/0/2
LAN2
PC 1
PC 2
Learn the mapping relationship between the MAC address and the interface (MAC
forwarding entry).
Be configured with static and blackhole MAC address entries.
Be enabled with or disabled from dynamic MAC address entry learning.
Be configured with the aging time of dynamic MAC entries.
Bridge all protocol packets (including IP and non-IP packets) by default.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Transparent Bridging Configuration
351