Configuration - Outputs (Option) - JUMO LOGOSCREEN 500 Operating Instructions Manual

Paperless recorder
Hide thumbs Also See for LOGOSCREEN 500:
Table of Contents

Advertisement

4 Configuration parameters
Start time
timed operation
End time
timed operation
Stored value
timed operation
Storage rate
timed operation

4.2.7 Configuration - Outputs (option)

Action
outputs
Operating signal
outputs
Action
outputs
60
Configuration
➔ Meas. storage
➔ Timed operation
➔ Start time
Configuration
➔ Meas. storage
➔ Timed operation
➔ End time
Configuration
➔ Meas. storage
➔ Timed operation
➔ Stored value
Configuration
➔ Meas. storage
➔ Timed operation
➔ Storage rate
Parameter
Configuration
➔ Outputs
➔ Relay K1
➔ Action
Configuration
➔Outputs
➔ Relay K1
➔ Operating signal
Configuration
➔Outputs
➔ Relay K2 — K3
➔ Action
any time
any time
Average val.,
Instant val.,
Minimum,
Maximum,
Peak value
1 — 5 — 32767s
Value/selection
Off,
n.o. (make),
n.c. (break)
Off,
Logic inp1 — 4,
Logic channel 1 — 6,
Low alarm 1 — 6,
Low comb. alarm,
High alarm 1 — 6,
High comb. al.,
Counter/I al. 1 — 6,
C/I comb. al.,
Comb. alarm,
Memory al.,
Error,
Modbus-Flag
Off,
n.o. (make),
n.c. (break)
Off when
start time =
end time
v Chapter 2.7 "Operating
modes"
Chapter 2.8 "Data
storage"
v Chapter 2.7 "Operating
modes"
Chapter 2.8 "Data
storage"
Description
The configured signal is
output to the relay.
If n.o. (break) or n.o. (make)
is selected, the parameter
Outputs is automatically
set to Low alarm 1 or Low
alarm 2.

Hide quick links:

Advertisement

Table of Contents
loading