3 Connecting the interface

3.4 Configuration of the serial interfaces

Configuration
on the
paperless
recorder
Configuration
via the setup
program
Device address
Interface type
Protocol
Baud rate
Transmission mode
(RTU)
Min. response time
12
Select Configuration
paperless recorder.
Now the parameters required to configure the interface are available.
The Edit
Serial interface
configuration by means of the setup software.
Parameters
Device address
Type
Protocol
Baud rate
Data format
Min. response time
For communication via the RS232 interfaces, the device address
has to be taken into account although it is not a bus interface.
The serial interfaces as well as the USB and Ethernet interface can
be operated simultaneously. Only on the protocol level, some
inhibits are present (e.g. only one setup may be written at a time).
Interface
RS232/RS485
RS232/RS485 menu point is used for the
Value/Selection
1 ... 254
RS232,
RS485
Modbus slave,
Modbus master,
Barcode
9600 baud,
19200 baud,
38400 baud
8 - 1 - no Parity,
8 -1 - odd Parity,
8 -1 - even Parity
0 ... 500ms
General on the
Description
see Chapter 4.5 Device
address, Page 18.
Can only be edited for
RS232/RS485.
See Chapter 3.3 Toggling
between RS232 and
RS485, Page 11.
see Chapter 5 Serial
protocol types, Page 35
see Chapter 4.3 Timing of
the communication, Page
16.
see Chapter 4.2
Transmission mode (RTU),
Page 15.
see Chapter 4.3 Timing of
the communication, Page
16.
.