Saving and Restoring Camera Settings

The parameters used to select, load and save user sets are grouped together under the Camera
Information set of features. There are 8 user sets available and one factory set.
Parameter
User Set Default Selector
User Set Selector
User Set Load
User Set Save
Description of the Camera Settings
The camera operates in one of three settings:
1. Current session.
2. User setting.
3. Factory setting (read-only).
4. Default setting.
The current settings can be saved (thereby becoming the user setting) using the User Set Save parameter.
A previously saved user setting (User Set 1 to 8) or the factory settings can be restored using the User Set
Selector and User Set Load parameters.
Either the Factory or one of the User settings can be saved as the Default Setting by selecting the set in the
User Set Default Selector. The chosen set automatically saves as the default setting and is the set loaded
w hen the camera is reset or pow ered up.
The relationship betw een these three settings is illustrated in Figure 18. Relationship betw een the Camera
Settings:
Teledyne DALSA
Camera Information
Select the camera parameters to load w hen the camera is reset or pow ered up as the
Factory set, or as User Set 1 to 8.
Selecting the set from the list automatically saves it as the default set.
Select the Factory or User set to Save or Load.
-Factory Set
-User Set 1 to 8.
Load the set specified by User Set Selector to the camera and make it the active /
current set.
Save the current set as selected user set.