8. Remove the four heater bracket retaining screws (T10); see Figure 050-8, Item 1.
9. Remove the heater/bracket assembly.

Figure 050-8: Steam Heater and Bracket

10. Unscrew the temperature sensor, temperature limiter and fuse from the heater; see
Figure 050-9, Items 1, 2 and 3.
11. Disconnect the heater electrical connection (yellow/green wire; sometimes secured
with a screw).

Figure 050-9: Temperature-Regulating Components on Steam Heater

Warning!
In order to avoid possible water system faults (e.g., clogging or blocking of
valves), grease, oil or other slip lubricants should never be used when
assembling and installing water system parts.
Technical Information
1 Temperature limiter
2 Temperature sensor
3 Fuse