Figure 051-14: Coffee/Hot Water And Steam Pumps - Miele CVA 4062 Technical Information

Coffee systems cva 406 series
Table of Contents

Advertisement

CVA 4062/CVA 4066/CVA 4068 Coffee Systems
9. The coffee/hot-water pump is shown in Figure 051-14, Item 1.

Figure 051-14: Coffee/Hot Water and Steam Pumps

10. Remove the spring clip from the Teflon hose connection on the pressure relief
valve and disconnect the Teflon hose; see Figure 051-15, Item 1.
11. Disconnect the two pump electrical connections.
12. Remove the four pump retaining screws (T10); see Figure 051-15, Item 2.
13. Remove the pump.
14. Pull the silicone hose off of the pump; see arrow, Figure 051-15.
15. Release the temperature limiter retainer using needlenose pliers and remove the
temperature limiter. See Figure 051-15, Item 3.
16. Unscrew the pressure relief valve; see Figure 051-15, Item 1.
17. Pull off the pump rubber brackets (top and bottom).
Technical Information
67
1 Coffee/hot-water pump
2 Steam pump