F41 -- Eeprom Faulty/Data Fault; F42 -- Line Frequency Not Registered; F47 -- No Communication Between Control And Power Electronics; F73 -- Brew Unit Fault - Miele CVA 4062 Technical Information

Coffee systems cva 406 series
Table of Contents

Advertisement

CVA 4062/CVA 4066/CVA 4068 Coffee Systems
3.8

F41 -- EEPROM Faulty/Data Fault

Cause:
EEPROM faulty/data fault.
Remedy:
1. See Control/Display Electronic EPWZ (N5) Removal, Section 025-4.1.
2. Install a new control/display electronic.
3.9

F42 -- Line Frequency Not Registered

Cause:
Frequency fluctuations or power-supply interference.
Remedy:
None.
3.10

F47 -- No Communication Between Control and Power Electronics

Cause:
Faulty interface between control and power electronics.
Remedy:
1. Check the wiring harness between the control electronic and the power electronic.
2. Replace the wiring harness, if necessary.
3.11

F73 -- Brew Unit Fault

Figure 070-1: Brew Unit Positioning Microswitches

After the brew unit is activated, if one of the two microswitches has not been activated
within approximately 10 seconds, fault code F73 is indicated.
Cause:
Brew unit jammed.
Remedy:
1. Switch off the appliance at the main switch.
2. Remove the brew unit from the appliance.
3. Check if the guide (Figure 070-2, Item 1) is correctly inserted in the brew unit.
Technical Information
1 Top positioning microswitch (basic setting) (S60/1)
2 Bottom positioning microswitch (pressure setting
and drainage setting) (S60/2)