CVA 4062/CVA 4066/CVA 4068 Coffee Systems
Figure 051-10: Rinsing and Hot-Water Solenoids
4. Remove the three spring clips from the rinsing solenoid water connections; see
Figure 051-11.
5. Remove the solenoid.
6. Disconnect all solenoid electrical connections.
Figure 051-11: Rinsing Solenoid
Warning!
In order to avoid possible water system faults (e.g., clogging or blocking of valves),
grease, oil or other slip lubricants should never be used when assembling and
installing water system parts.
Technical Information
1 Rinsing solenoid
2 Hot-water solenoid
65