Process Values (R41,010 – R41,048)
Rate, Load, Speed and Total (R41,010 – R41,019)
The associated registers provide the readings of rate, load, and speed. Totalizer 1 and
Totalizer 2 in engineering units as displayed in the local BW500 display.
Device State (41,020 – 41,020)
The Device State word is used to feedback the current operating state of the product.
Each bit gives the state of different parts of the product, some mutually exclusive, others
are not. The state should be checked to verify any device commands.
Bit #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Page 92
Description
PID 1 Mode
PID 1 Freeze
PID 1 Setpoint Source
PID 2 Mode
PID 2 Freeze
PID 2 Setpoint Source
Zero
Span
-
-
-
-
Write Privileges
System Configured
Mode
Totalizing
Milltronics BW500 – INSTRUCTION MANUAL
Bit Clear
Manual
No
Local
Manual
No
Local
No
No
-
-
-
-
No
Not Configured
Calibration Mode
Not Totalizing
Bit Set (1)
Auto
Yes
Remote
Auto
Yes
Remote
In progress
In progress
-
-
-
-
Yes
Yes
RUN Mode
Totalizing
7ML19985DK03