Siemens milltronics BW500 Instruction Manual page 110

Hide thumbs Also See for milltronics BW500:
Table of Contents

Advertisement

P009
Time
Enter the current time in
Where:
hh=hour
mm=minute
ss=second
P011
Design Rate
Specifies the design rate of material flow for the belt scale.(
Enter the design rate in the units selected (P005).
P014
Design Speed
Specifies the design speed for the conveyor belt. (
Speed units are:
feet/min
if the imperial system of measurement has been selected, P004 = 1
metres/s
if the metric system of measurement has been selected, P004 = 2
P015
Speed Constant
Set the speed constant for the speed sensor selected (P015-01 or 02).
The value in P015-01 is used with the speed sensor frequency, to calculate the actual belt
f
speed.(
= 0.000).
The value in P015-02 is used for differential speed detection.
Entry: If speed input is wired for constant speed (terminals 17/18 jumpered), value
defaults to jumpered, and the second speed sensor is ignored..
If the speed input is connected to a speed sensor, press
to P690. Refer to
P016
Belt Length
The length of the conveyor belt (one belt revolution). (
Length units are:
feet:
if the imperial system of measurement has been selected, P004 = 1
metres:
if the metric system of measurement has been selected, P004 = 2
Enter the belt length.
Page 104
hh-mm-ss
24 hour format.
P690
on page 126 for speed constant entry.
Milltronics BW500 - INSTRUCTION MANUAL
f
= 0.00)
f
= 0.00)
. P015 automatically jumps
f
= 0.000)
7ML19985DK03

Advertisement

Table of Contents
loading

Table of Contents