Scale – Four Load Cell
Siemens
Belt Scale
Where separation between the BW500 and belt scale exceeds 150 m (500 ft.), or legal for
trade certification:
1.
remove the jumpers from BW500 terminal 11/12 and 13/14
2.
run additional conductors from:
BW500 terminal 12 to scale `red'
BW500 terminal 13 to scale `blk'
If the load cell wiring colours vary from those shown, or if extra wires are provided,
consult Siemens.