Material Test; Design Changes - Siemens milltronics BW500 Instruction Manual

Hide thumbs Also See for milltronics BW500:
Table of Contents

Advertisement

Material Test

Access P019 and enter EDIT mode
P019 Manual Span Adjust
Select 1-% Change 2-Material Test
Press
Material Test
Add to Totalizer 0-No, 1-Yes
Press
Material Test
Press ENTER to start
Press
Material Test
Press ENTER key to stop
Press
Material Test
Enter actual amount
Press
Material Test Deviation
Accept 0-No, 1-Yes
Press
P017 Test Load Weight: MS1
Enter Test Load
Verify the results of the span adjust by material test or return to normal operation.

Design Changes

Where parameters have been changed with a resultant impact on the calibration, they do
not take effect until a recalibration is done.
If significant changes have been made, an initial zero (P377) and/or initial span (P388)
may be required (see page 117).
7ML19985DK03
Milltronics BW500 – INSTRUCTION MANUAL
E
0
if yes, the weight of the material test
will be added to the totalizer, if no,
material is added to test totalizer (4)
only.
e.g. do not add weight of material test
to totalizer
the totalizer reading as the material test
#.###
is run
e.g. the weight totalized by the belt
964.032
scale and BW500
e.g. 975.633 kg is the actual weight of
the material test
e.g. the calculated deviation is
-1.19
displayed as a % of the actual weight
e.g. the new test load value is
displayed.
V
56.78
Page 37

Advertisement

Table of Contents
loading

Table of Contents