Read/Write (R41,025 – R41,026) Total Decimal Places
Sets the number of decimal places (0-3) being read for Total 1, (words 41,016 and 41,017)
and Total 2, (words 41,018 and 41,019).
With 3 decimal places, the largest value that can be read is 2,147,483.648.
With 2 decimal places, the largest value that can be read is 21,474,836.48.
With 1 or 0 decimal places, the largest value that can be read is 100,000,000.
Example: R41,025
Bits 0 and 1 are used to indicate the number of decimal places being read in Total 1,
Words 7 and 8.
Bit 15 is used to indicate if the decimal place is too large to read the total value correctly.
If three decimal places are being read in Total 1:
Bits
15
14
0
0
If three decimal places are being read in Total 1, and the value is too large to be read with
three decimal places:
Bits
15
14
1
0
Page 94
13
12
11
10
1
0
0
1
13
12
11
10
1
0
0
1
Milltronics BW500 – INSTRUCTION MANUAL
9
8
7
6
5
0
0
0
0
0
9
8
7
6
5
0
0
0
0
0
4
3
2
1
0
0
0
0
1
1
4
3
2
1
0
0
0
0
1
1