Factoring - Siemens milltronics BW500 Instruction Manual

Hide thumbs Also See for milltronics BW500:
Table of Contents

Advertisement

1.
Rerun on-line calibration to verify the deviation: press
2.
Verify the mechanics of the belt scale: carry out material tests to ensure the
readings are correct. (See page 35,)
3.
If the mechanics are functioning correctly, perform an initial span using P388. (See
page 42.)

Factoring

For optimum accuracy in the factoring results, a routine zero calibration is
Note:
recommended.
To calculate the value of a new or unknown test weight to the current span, the factoring
procedure is used.
With the conveyor stopped and the belt empty:
Access P359 in VIEW mode
P359 Factoring
Select 1-Weight, 2-Chain
Press
Factoring Weight
Place weight and press ENTER.
Press
Factoring Weight
Factoring in progress
Factoring Weight
Press ENTER to accept value
Press
P017 Test Load Weight:
Enter Test Load
If multispan function is used, the test load value is stored for the current
Note:
multispan only.
Page 50
##.## kg/m
Milltronics BW500 – INSTRUCTION MANUAL
e.g. factor the test weight
the load reported while factoring is in
progress.
e.g. the new factor, if accepted
45.25
e.g. the current test load value
V
factoring is complete. Return to
45.25
RUN mode if so desired
to return to P358.
7ML19985DK03

Advertisement

Table of Contents
loading