Communication (P750 - P799); Smartlinx Hardware Testing - Siemens milltronics BW500 Instruction Manual

Hide thumbs Also See for milltronics BW500:
Table of Contents

Advertisement

P739
Time Zone
The offset from Greenwich mean time (GMT) of local time.
This parameter does not affect any timed events because all times are local. It can be
accessed by a remote computer for synchronization purposes.
Enter local time zone –12 to 12

Communication (P750 - P799)

These parameters cover the various communications formats supported by the BW500:
serial printer, Dolphin Plus, SmartLinx ® , and Modbus.
P750 – P769 SmartLinx
These parameters are specific to the SmartLinx ® module installed. Refer to the module
documentation for a list and description of the specific parameter requirements.
P770 – P789 Local Port Parameters
These parameters are specific to programming of the BW500 communication ports. Refer
Communications
to

SmartLinx Hardware Testing

These parameters are used to test and debug a SmartLinx card (if installed).
P790 Hardware Error
The results of ongoing hardware tests in the communications circuitry.
Values
PASS
FAIL
ERR1
If FAIL or ERR1 is displayed in P790 (Hardware Error), go to P791 (Hardware Error Code)
and P792 (Hardware Error Count) for information about the error.
P791 Hardware Error Code
Indicates the precise cause of Fail or ERR1 condition from P790.
Values
7ML19985DK03
Milltronics BW500 - INSTRUCTION MANUAL
®
Module Specific Parameters
on page 76 for a listing and description of these parameters.
Description
*
No errors
Error occurred communicating with card; device will try to reinitial-
ize communications with card. If message continues, record values
in P791 and P792 and contact your local Siemens representative.
No module installed, or module not supported; communications
have been disabled
Description
Page 129