Zero Calibration

To obtain an accurate and successful calibration, ensure that the required
Note:
criteria are met. Refer to
Press
Zero Calibration: Current Zero
Clear belt. Press ENTER to Start
Press
Initial Zero Calibration. In progress
Current Reading:
The duration of the Zero calibration is dependent upon speed (P014),length (P016) and
revolutions (P360) of the belt.
Press
Calibration Complete. Deviation
Press ENTER to accept value:
Press
Zero Calibration. Current Zero
Clear belt. Press ENTER to Start
Accepting the Zero returns to start of Zero. A new Zero can be performed, or continue to
.
Span
The moisture meter is ignored during calibration. If Inclinometer is used, then
Note:
calibration is adjusted based on incline angle.
Span Calibration
When performing a Span Calibration where the test reference is ECal (P002 = 3), the
supplied test weight or test chain must not be applied, and the conveyor must be run
empty.
To obtain an accurate and successful calibration, ensure that the required
Note:
criteria are met. Refer to
With the conveyor stopped and locked out, apply the test weight or chain to the scale as
instructed in the associate manuals; Then start the conveyor.
Press
Span Calibration. Current Span
Setup test. Press ENTER to Start
Page 32
Calibration Criteria
Calibration Criteria
Milltronics BW500 - INSTRUCTION MANUAL
on page 140.
0
the current zero count
the zero count being calculated
while calibration is in progress
#####
the deviation from previous zero. For
an initial zero there is no previous
zero; hence the deviation is 0.
0.00
551205
for example, the new zero count, if
accepted
551205
for example, the new zero count, if
accepted
on page 140.
the current span count
0
7ML19985DK03