Siemens milltronics BW500 Instruction Manual page 54

Hide thumbs Also See for milltronics BW500:
Table of Contents

Advertisement

Access
P255-01 mA Input Function
Select 0, 1-PID SP, 2-PID FV, 3-OCAL
Press
Assign one of the 5 relays, P100-01 to P100-05, to the On-line Calibration function.
Access
P100-01 Relay Function
Select Function [0-9] (see manual)
Press
Program the assigned relay using P118, relay logic, so that when you connect the
assigned relay to the weigh bin material feed control device, the weigh bin material feed
stops when the On-Line relay is energized.
Activate On-line Calibration.
Access
P358 On-line Calibration Features
0-OFF,
Press
For remote access, On-line Calibration can also be activated using one of the
Note:
Auxiliary inputs (refer to
When the On-line Calibration is activated, normal operation continues until the weigh bin
fills to the maximum level, (90% in the example shown). During the filling stage, the
current level is displayed as a percentage.
On-line Calibration -
Wait for LEVEL > MAX
When the maximum limit is reached, the relay assigned to the On-line Calibration function
energizes to stop the weigh bin material feed.
On-line Calibration -
Wait for LEVEL < HIGH
Material continues to be discharged from the weigh bin, and when the level drops to the
High limit (70% in the example) the On-Line totalizer is automatically activated.
On-line Calibration -
Calibration in progress
When the Low limit (30%) is reached, the totalizer is deactivated and the assigned relay is
de-energized, which reopens the material feed to the weigh bin.
Page 48
1-ACTIVE
P270
on page 112).
LOW > 19%
RLY
94% > MAX
RLY 1
TOTAL 3.71 tonnes
RLY 1
Milltronics BW500 – INSTRUCTION MANUAL
V
3
e.g. mA input 1 set to 3
V
e.g. relay 1 set to 9
9
V
1
current level displayed as percentage
running total
7ML19985DK03

Advertisement

Table of Contents
loading

Table of Contents