Run Mode - Siemens milltronics BW500 Instruction Manual

Hide thumbs Also See for milltronics BW500:
Table of Contents

Advertisement

Press
Initial Span Calibration. in progress
Current Reading
The duration of the Span calibration is dependent upon speed (P014), length (P016) and
revolutions (P360) of the belt.
Span Count too Low.
Press CLEAR to continue.
Press
Calibration Complete. Deviation
Press ENTER to accept value:
Press
Span Calibration. Current Span
Setup test. Press ENTER to Start
Accepting the Span returns to start of Span. A new Span can be performed, or enter RUN
mode. If calibrating with a test weight or test chain, remove it from the scale and store in
a secure place before returning to RUN mode.
The moisture meter is ignored during calibration. If the Inclinometer is used,
Note:
then calibration is adjusted based on incline angle.

RUN Mode

Proper programming and successful zero and span calibration allow entry into the RUN
mode. Otherwise, entry is denied and the first missing item of programming or calibration
is displayed.
Press
Rate
Total 1
Once the initial programming is complete and the BW500 is operating in the RUN mode,
you may now put the belt conveyor into normal service. The BW500 is functioning under
its initial program and calibration, reporting rate of material flow and totalizing.
If the initial entry and operation in the RUN mode is successful, recalibrate the weighing
system by performing a series of material tests. Material tests verify that the BW500
reporting accurately. Where inaccuracies exist, correct the system through a manual
span adjustment (P019).
Perform recalibration of the zero and span routinley to maintain accurate reporting of rate
and total.. Refer to
7ML19985DK03
Milltronics BW500 - INSTRUCTION MANUAL
if
0.00 kg/h
0.00 kg
Recalibration
, page 34.
0
the span count being calculated
while calibration is in progress
####
signal from load cell too low, insure
proper test weight or chain is applied
during calibration
check for proper load cell wiring
the deviation from the previous span.
For an initial span, there is no previous
0.00
span count; hence the deviation is 0.
36790
for example, the new span count,
if accepted.
36790
for example, the current span
count
e.g. if there is no material on the belt
and the conveyor is running. The
current rate is 0 and no material has
been totalized.
Page 33

Advertisement

Table of Contents
loading

Table of Contents