Startup For The Fe And Qfe 4.3-18 Kva Ups - Powerware Ferrups FE/QFE UPS User Manual

500 va–18 kva,50 and 60 hz
Table of Contents

Advertisement

Startup for the FE and QFE 4.3–18 kVA UPS
To start the FE and QFE 4.3–18 kVA UPS, use the following steps:
1. Confirm the equipment to be protected by the UPS is powered
2.
NOTE If the plug does not match your receptacle outlet, ask your electrician to install
the proper outlet.
3. If your UPS has a DC switch, turn on the switch according to
4.
Powerware
®
FERRUPS FE/QFE UPS (500 VA–18 kVA) User's Guide
off.
For Plug-Receptacle UPSs:
at the service panel. Plug the UPS power cord into a power
outlet.
Confirm that an electrician has completed
For Hardwired UPSs:
and tested the connection to the proper power source and
connected your protected equipment according to the
Powerware FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation
Guide. Confirm that your AC line disconnect switch and the
UPS ON/OFF switch are both in the OFF position.
the UPS model:
If you have an external battery cabinet(s) with a DC
4.3–7 kVA:
switch, turn the switch to the ON position.
If you do not have an external battery cabinet(s): unlock the
UPS front cover panel using the FERRUPS key and remove the
front cover panel. Locate the DC switch behind the UPS front
cover panel. If there is a precharge button next to the switch,
press it for a few seconds. Turn the DC switch to the ON
position and reinstall the UPS front cover panel.
If you have an external battery cabinet(s) with a DC
10–18 kVA:
switch, turn the switch to the ON position.
Starting the UPS on battery power:
ON/OFF switch to the ON position. After a brief self-check, the
BATTERY POWER and READY indicators illuminate. The UPS
beeps every 20 seconds, indicating the UPS is running on
battery power. The control panel scrolls this display:
Rev A www.powerware.com
Verify that the AC input power is off
Use the key to turn the
UPS Startup
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ferrups feFerrups qfe

Table of Contents