Saving of parameter settings
After power on of the CTVideo sensor the flash mode is active. It means, changed parameter settings will be
saved in the internal Flash-EEPROM and will be kept also after the sensor is switched off.
In case settings should be changed quite often or continuously the flash mode can be switched off by using
the following command:
Decimal:
112
HEX:
0x70
Data, Answer:
byte 1 (0x01 or 0x00)
Parameter, result: 01 – Data will not be written into the flash memory
00 – Data will be written into the flash memory
Complete command sequences with checksum: 0x 70 01 71
If the flash mode is deactivated, all settings will only be kept as long as the CTVideo unit is powered. If the
unit is switched off and powered on again all previous settings are lost.
The command 0x71 will poll the current status.
You will find a detailed protocol and command description on the software CD in the directory: \Commands.
thermoMETER CTVideo
0x 70 01 70