Electrical Specifications
Power Supply
Current draw
Aiming laser
Video sighting
Output/ analog
Alarm output
Output impedances
mA
mV
Thermocouple
Digital interface
Functional inputs
thermoMETER CTVideo
8 – 36 VDC
max. 160 mA
635 nm, 1 mW, On/ Off via programming keys or software
Digital (USB 2.0), 640 x 480 px, FOV 3.1° x 2.4°
Selectable: 0/ 4 – 20 mA, 0 – 5/ 10 V, thermocouple (J or K) or alarm output
(Signal source: object temperature)
Open collector output at Pin AL2 [24 V/ 50 mA]
max. loop resistance 500 Ω (at 8 - 36 VDC),
min. 100 KΩ load impedance
20 Ω
USB 2.0
F1-F3; software programmable for the following functions:
- external emissivity adjustment,
- ambient temperature compensation,
- trigger (reset of hold functions)
Input impedance F2 and F3: 43 kΩ
9
Need help?
Do you have a question about the CTVM-1L and is the answer not in the manual?