5. OTHER MAINTENANCE ITEMS
5.4.12

Multi bypass tray

1. Remove the rear right cover/1.
See P.34
[2]
[2]
6. To reinstall, reverse the order of removal.
40
[1]
A0XXF2E510DA
[2]
[1]
A0XXF2E511DA
[1]
A0XXF2E027DA
Field Service Ver. 2.0 Jun. 2010
2. Remove the screw [1], and remove
the cover [2].
3. Remove the harness from the wire
saddle [1].
4. Disconnect the connector [2].
5. Remove four screws [1], and remove
the multi bypass tray [2].