Prn Sub (Tray1-P) - Konica Minolta bizhub 164 Service Manual

Hide thumbs Also See for bizhub 164:
Table of Contents

Advertisement

Field Service Ver. 2.0 Jun. 2010
11.4.3

PRN SUB (TRAY1-P)

A. Use
• To adjust by varying the starting position of image writing in the sub scanning direction.
• Used when the image on the copy deviates in the sub scanning direction.
• Used when the PH unit has been replaced.
B. Procedure
• Adjust so that width A on the test pattern produced falls within the specified range.
• Specifications: 10 ± 1.5 mm
70 (-4.62 mm) to 130 (+4.62 mm) (1 step: 0.154 mm)
1. Load the tray 1 with A3/11 x 17 plain paper.
1
2. Enter function of the SERVICE MODE.
3. Select [FUNCTION] → [PRN TEST PATTERN] → [TRAY1] → [TEST PATTERN1].
1
Then, press the Menu/Select key.
This will produce a test pattern.
4. Check to see if width A on the test pattern falls within the specified range.
If width A falls outside the specified range, perform the following steps to make an
adjustment.
5. Select [PRN SUB (TRAY1-P)] of [ADJUST].
6. Using [ ▲ / ▼ ] key, select the appropriate setting value.
If width A on the test pattern is longer than the specifications, decrease the setting
value.
If width A on the test pattern is shorter than the specifications, increase the setting
value.
7. Press the Menu/Select key to validate the setting value selected in step 6.
1
8. If a single adjustment procedure does not successfully bring width A into the specified
range, repeat steps 5 through 7.
11. SERVICE MODE
A
A0XXF3C505DA
95
1

Hide quick links: