Field Service Ver. 2.0 Jun. 2010
4.1.5
Application of toner
NOTE
• Perform these steps when the drum and/or cleaning blade have been replaced.
10 to 15 mm
Drum
4. PERIODICAL MAINTENANCE PROCEDURE
1. With the imaging unit divided into the
[1]
A0XXF2E529DA
<<Area to which toner is to be applied>>
20 to 25 mm
A09AF2C505DA
2. Using a brush, apply a light coat of
[1]
A0XXF2E530DA
drum assy and developing assy,
install the drum positioning jig [1] in
the rear of the drum assy.
toner to the surface of the drum [1].
17