Original Glass - Konica Minolta bizhub 164 Service Manual

Hide thumbs Also See for bizhub 164:
Table of Contents

Advertisement

5. OTHER MAINTENANCE ITEMS
5.4.9

Original glass

1. Remove the left cover.
See P.33
2. Remove the scanner right cover.
See P.35
3. Remove the operation panel.
See P.39
4. Remove the rear cover.
See P.34
5. Remove the scanner rear cover.
See P.35
6. Remove the toner bottle.
See P.19
7. Remove the imaging unit.
See P.41
8. Remove the front cover.
See P.33
9. Remove the paper exit tray (left) and paper exit tray (right).
See P.36
[2]
[1]
0 to 0.5mm
38
10. Remove twelve screws [1], and
[1]
[1]
A0XXF2E026DA
11. To reinstall, reverse the order of
0 to 0.5mm
NOTE
• When affixing the scale label
[1]
A0XXF2C540DA
Field Service Ver. 2.0 Jun. 2010
remove the original glass [2].
removal.
(A0XXPP7B00) [1] during the
replacement of the original glass,
align the left and rear edges of the
scale label with the left and rear
protrusions on the main body.