Field Service Ver. 2.0 Jun. 2010
4.2
Conveyance section
4.2.1
Cleaning of the timing roller
A. Periodically cleaning parts/cycle
• Timing roller: Every 55,000 counts
B. Procedure
1. Open the right door.
1
[1]
4.2.2
Cleaning of the pre-image transfer guide plate
A. Periodically cleaning parts/cycle
• Pre-image transfer guide plate: Every 55,000 counts
B. Procedure
1. Remove the toner bottle.
See P.19
2. Remove the imaging unit.
See P.41
[1]
4. PERIODICAL MAINTENANCE PROCEDURE
2. Using a cleaning pad dampened with
A0XXF2E012DA
3. Release the tabs [1] and disconnect
[2]
A0XXF2E513DA
alcohol, wipe the timing roller [1]
clean of dirt.
the connector [2] from the imaging
unit.